|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
V436632Y24V 256MB 144-PIN UNBUFFERED SDRAM SODIMM, 32M X 64 3.3VOLT PRELIMINARY Features JEDEC-standard 144 pin, Small-Outline, Dual in line Memory Module (SODIMM) Serial Presence Detect with E2PROM Nonbuffered Fully Synchronous, All Signals Registered on Positive Edge of System Clock Single +3.3V ( 0.3V) Power Supply All Device Pins are LVTTL Compatible 8192 Refresh Cycles every 64 ms Self-Refresh Mode Internal Pipelined Operation; Column Address can be changed every System Clock Programmable Burst Lengths: 1, 2, 4, 8 Auto Precharge and Piecharge all Banks by A10 Data Mask Function by DQM Mode Register Set Programming Programmable (CAS Latency: 2, 3 Clocks) TSOP component package CILETIV LESO M 32M x 8 Description The V436632Y24V memory module is organized 33,554,432 x 64 bits in a 144 pin SODIMM. The 32M x 64 memory module uses 8 Mosel-Vitelic 16M x 16 SDRAM. The x64 modules are ideal for use in high performance computer systems where increased memory density and fast access times are required. Speed Grade -75PC, CL=2,3 (133 MHz) -75, CL=3 (133 MHz) -10PC, CL=2,3 (100 MHz) Part Number V436632Y24VXTG-75PC Configuration 32M x 64 V436632Y24VXTG-75 32M x 64 V436632Y24VXTG-10PC 32M x 64 32M x 8 32M x 8 32M x 8 1 59 61 143 Pin 2 on Backside Pin 144 on Backside V436632Y24V Rev.1.2 March 2002 1 V436632Y24V Front DQMB1 DQMB5 VDD VDD A0 A3 A1 A4 A2 A5 VSS VSS DQ8 DQ40 DQ9 DQ41 DQ10 DQ42 DQ11 DQ43 VDD VDD DQ12 DQ44 Pin 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 Front DQ13 DQ45 DQ14 DQ46 DQ15 DQ47 VSS VSS NC NC NC NC CLK0 CKE0 VDD VDD RAS CAS WE CKE1 CS0 NC CS1 A12 Pin 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 Back NC CLK1 VSS VSS NC NC NC NC VDD VDD DQ16 DQ48 DQ17 DQ49 DQ18 DQ50 DQ19 DQ51 VSS VSS DQ20 DQ52 DQ21 DQ53 Pin 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 Back DQ22 DQ54 DQ23 DQ55 VDD VDD A6 A7 A8 BA0 VSS VSS A9 BA1 A10 A11 VDD VDD DQMB2 DQMB6 DQMB3 DQMB7 VSS VSS Pin 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 Back DQ24 DQ56 DQ25 DQ57 DQ26 DQ58 DQ27 DQ59 VDD VDD DQ28 DQ60 DQ29 DQ61 DQ30 DQ62 DQ31 DQ63 VSS VSS SDA SCL VDD VDD CILETIV LESO M Pin Configurations (Front Side/Back Side) Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Front VSS VSS DQ0 DQ32 DQ1 DQ33 DQ2 DQ34 DQ3 DQ35 VDD VDD DQ4 DQ36 DQ5 DQ37 DQ6 DQ38 DQ7 DQ39 VSS VSS DQMB0 DQMB4 Pin 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Note: 1. RAS, CAS, WE CASx, CSx are active low signals. Pin Names A0-A12, BA0, BA1 DQ0-DQ63 RAS CAS WE CS0, CS1 DQMB0-DQMB7 CKE0, CKE1 CLK0, CLK1 SDA SCL VDD VSS NC Address, Bank Select Data Inputs/Outputs Row Address Strobes Column Address Strobes Write Enable Chip Select Output Enable Clock Enable Clock Serial Input/Output Serial Clock Power Supply Ground No Connect (Open) V436632Y24V Rev. 1.2 March 2002 2 V436632Y24V CILETIV LESO M Part Number Information V MOSEL VITELIC MANUFACTURED 4 3 66 32 Y2 4 V XT G - XX SDRAM 3.3V WIDTH DEPTH 144 PIN SODIMM X16 COMPONENT REFRESH RATE 8K SPEED 75PC = PC133 CL2,3 75 = PC133 CL3 10PC = PC100 CL2,3 LEAD FINISH G = GOLD COMPONENT PACKAGE, T=TSOP COMPONENT A=0.17u B=0.14u REV LEVEL LVTTL 4 BANKS Block Diagram CS0 WE WE CS UDQM U0 DQMB1 LDQM DQ8-15 DQMB5 WE CS UDQM U2 LDQM DQ40-47 DQMB0 DQ0-7 DQMB4 DQ32-39 DQMB2 WE CS UDQM U1 DQ16-23 DQMB6 WE CS UDQM U3 DQ43-54 DQMB3 LDQM DQ24-31 DQMB7 LDQM DQ55-63 CS1 WE WE CS UDQM U4 DQMB1 LDQM DQ8-15 DQMB5 WE CS UDQM U6 LDQM DQ40-47 DQMB0 DQ0-7 DQMB4 DQ32-39 DQMB2 WE CS UDQM U5 DQ16-23 DQMB6 WE CS UDQM U7 DQ43-54 DQMB3 LDQM DQ24-31 DQMB7 LDQM DQ55-63 VDD VSS A0-A11, BA0, BA1 CKE0 CKEI RAS CAS U0-U7 CLK0 U0-U7 U0-U3 U4-U7 U0-U7 U0-U7 SCL SPD A0 A1 A2 CLKI 0 U0, U1 U2, U3 U4, U5 0 U6, U7 SDA Note: All resistors are 10 Ohms V436632Y24V Rev. 1.2 March 2002 3 V436632Y24V E2PROM device during module production using a serial presence detect protocol (I2C synchronous 2-wire bus) A serial presence detect storage device - E2PROM is assembled onto the module. Information about the module configuration, speed, etc. is written into the CILETIV LESO M Serial Presence Detect Information SPD-Table for modules: Byte Number 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Hex Value Function Described Number of SPD bytes Total bytes in Serial PD Memory Type Number of Row Addresses (without BS bits) Number of Column Addresses ( x16 SDRAM) Number of DIMM Banks Module Data Width Module Data Width (continued) Module Interface Levels SDRAM Cycle Time at CL=3 SDRAM Access Time from Clock at CL=3 Dimm Config (Error Det/Corr.) Refresh Rate/Type SDRAM width, Primary Error Checking SDRAM Data Width Minimum Clock Delay from Back to Back Random Column Address Burst Length Supported Number of SDRAM Banks Supported CAS Latencies CS Latencies WE Latencies SDRAM DIMM Module Attributes SDRAM Device Attributes: General Minimum Clock Cycle Time at CAS Latency = 2 SPD Entry Value 128 256 SDRAM 13 9 2 64 0 LVTTL 7.5 ns/10.0 ns 5.4 ns/10.0ns none Self-Refresh, 7.8 s x16 n/a / x16 tccd = 1 CLK 1, 2, 4 & 8 4 CL = 2 / 3 CS Latency = 0 WL = 0 Non Buffered/Non Reg. Vcc tol 10% 7.5 ns/10.0 ns & Not Supported 7.5ns/10.0ns & Not Supported Not Supported Not Supported -75PC 80 08 04 0D 09 02 40 00 01 75 54 00 82 10 00 01 -75 80 08 04 0D 09 02 40 00 01 75 54 00 82 10 00 01 -10PC 80 08 04 0D 09 02 40 00 01 A0 60 00 82 10 00 01 16 17 18 19 20 21 22 23 0F 04 06 01 01 00 0E 75 0F 04 06 01 01 00 0E A0 0F 04 06 01 01 00 0E A0 24 Maximum Data Access Time from Clock for CL =2 Minimum Clock Cycle Time at CL = 1 Maximum Data Access Time from Clock at CL =1 Minimum Row Precharge Time Minimum Row Active to Row Active Delay tRRD 54 60 60 25 26 00 00 00 00 00 00 27 28 15 ns / 20 ns 14 ns/15 ns/16 ns 0F 0E 14 0F 14 10 V436632Y24V Rev. 1.2 March 2002 4 V436632Y24V CILETIV LESO M SPD-Table for modules: (Continued) Byte Number 29 30 31 64 33 34 35 62-61 62 63 64 65-71 72 73-90 91-92 93 94 95-98 Hex Value Function Described Minimum RAS to CAS Delay tRCD Minimum RAS Pulse Width tRAS Module Bank Density (Per Bank) SDRAM Input Setup Time SDRAM Input Hold Time SDRAM Data Input Setup Time SDRAM Data Input Hold Time Superset Information (May be used in Future) SPD Revision Checksum for Bytes 0 - 62 Manufacturer's JEDEC ID Code Manufacturer's JEDEC ID Code (cont.) Manufacturing Location Module Part Number (ASCII) PCB Identification Code Assembly Manufacturing Date (Year) Assembly Manufacturing Date (Week) Assembly Serial Number 1 = US, 2 = Taiwan V436632Y24V Current PCB Revision Binary Coded year (BCD) Binary Coded week (BCD) byte 95 = LSB, byte 98 = MSB 00 64 00 64 00 64 Mosel Vitelic Revision 2 / 1.2 SPD Entry Value 15 ns/20 ns 42 ns/45 ns 128 Mbyte 1.5 ns/2.0 ns 0.8 ns/ 1.0 ns 1.5 ns/2.0 ns 0.8 ns/1.0 ns -75PC 0F 2A 20 15 08 15 08 00 02 E5 40 00 -75 14 2D 20 15 08 15 08 00 02 2A 40 00 -10PC 14 2D 20 20 10 20 10 00 12 98 40 00 99-125 126 127 128+ Reserved Intel Specification for Frequency Supported Frequency Unused Storage Location 00 00 00 V436632Y24V Rev. 1.2 March 2002 5 V436632Y24V CILETIV LESO M DC Characteristics TA = 0C to 70C; VSS = 0 V; VDD, VDDQ = 3.3V 0.3V Limit Values Symbol VIH VIL V OH VOL II(L) IO(L) Parameter Input High Voltage Input Low Voltage Output High Voltage (IOUT = -4.0 mA) Output Low Voltage (IOUT = 4.0 mA) Input Leakage Current, any input (0 V < VIN < 3.6 V, all other inputs = 0V) Output leakage current (DQ is disabled, 0V < VOUT < VCC) Min. 2.0 -0.5 2.4 -- -10 Max. VCC +0.3 0.8 -- 0.4 10 Unit V V V V A A -10 10 Capacitance Symbol CI1 CI2 CICL CI3 CI4 CSC CIO TA = 0C to 70C; VDD = 3.3V 0.3V, f = 1 MHz Parameter Input Capacitance (A0 to A11, RAS, CAS, WE) Input Capacitance (CS0, CSI) Input Capacitance (CLK0-CLK1) Input Capacitance (CKE0, CKEI) Input Capacitance (DQMB0-DQMB7) Input Capacitance (SCL, SA0-2) Input/Output Capacitance Limit Values (Max.) 40 25 28 20 10 8 18 Unit pF pF pF pF pF pF pF Absolute Maximum Ratings Parameter Voltage on VDD Supply Relative to V SS Voltage on Input Relative to VSS Operating Temperature Storage Temperature Power Dissipation Max. -1 to 4.6 -1 to 4.6 0 to +70 -55 to 125 6.5 Units V V C C W V436632Y24V Rev. 1.2 March 2002 6 V436632Y24V Symbol ICC1 CILETIV LESO M Standby and Refresh Currents1 TA = 0C to 70C, VCC = 3.3V 0.3V Parameter Operating Current Test Conditions Burst length = 4, CL = 3 tRC> = tRC(min), tCK> = tCK(min), IO = 0 mA 2 Bank Interleave Operation CKE< = VIL(max), tCK> = tCK(min) CKE> = VIH(min), tCK> = tCK(min), Input changed once in 3 cycles 75PC/75 920 10PC 680 Unit mA Note 1,2 ICC2P ICC2N Precharged Standby Current in Power Down Mode Precharged Standby Current in Non-Power Down Mode 16 16 mA 160 120 mA CS = High ICC3P ICC3N ICC4 Active Standby Current in Power Down Mode CKE< = VIL(max), tCK> = tCK(min) 80 80 mA Active Standby Current in Non-Pow- CKE> = VIH(min), tCK> = tCK(min), Iner Down Mode put changed one time Burst Operating Current Burst length = Full Page, tRC = Infinite, CL = 3, tCK> = tCK(min), IO = 0 mA 2 Banks Activated tRC>= tRC(min) CKE = <0.2 V Standard L-Version 200 180 mA CS = High 600 400 mA 1, 2 ICC5 ICC6 Auto Refresh Current Self Refresh Current 1920 24 13.6 1760 24 13.6 mA mA 1,2 1,2 V436632Y24V Rev. 1.2 March 2002 7 V436632Y24V CILETIV LESO M AC Characteristics 3,4 TA = 0 to 70C; VSS = 0V; VCC = 3.3V 0.3V, tT = 1 ns Limit Values -75PC # Symbol Parameter Min. Max. Min. -75 Max. -10PC Min. Max. Unit Note Clock and Clock Enable 1 tCK Clock Cycle Time CAS Latency = 3 CAS Latency = 2 System frequency CAS Latency = 3 CAS Latency = 2 Clock Access Time CAS Latency = 3 CAS Latency = 2 Clock High Pulse Width Clock Low Pulse Width Input Setup time Input Hold Time CKE Setup Time (Power down mode) CKE Setup Time (Self Refresh Exit) Transition time (rise and fall) 7.5 7.5 - - - - 2.5 2.5 1.5 0.8 2 8 1 133 133 5.4 6 - - - - - - - 7.5 10 - - - - 2.5 2.5 1.5 0.8 2 8 1 133 100 5.4 6 - - - - - - - 10 10 - - - - 3 3 2 1 2 8 1 100 100 6 6 - - - - - - - ns ns MHz MHz 4,5 ns ns ns ns ns ns ns ns ns 6 6 7 7 8 9 2 fCK 3 tAC 4 5 6 7 8 9 10 tCH tCL tCS tCH tCKSP tCKSR tT Common Parameters 11 12 13 14 15 16 tRCD tRC tRAS tRP tRRD tCCD RAS to CAS delay Cycle Time Active Command Period Precharge Time Bank to Bank Delay Time CAS to CAS delay time (same bank) 15 70 42 15 14 1 - 120k - - - - 20 70 45 20 15 1 - 120k - - - - 20 70 45 20 20 1 - 120k - - - - ns ns ns ns ns CLK Refresh Cycle 17 18 tSREX tREF Self Refresh Exit Time Refresh Period (8192 cycles) 10 64 - - 10 64 - - 10 64 - - ns ms 9 8 Read Cycle 19 20 21 22 tOH tLZ tHZ tDQZ Data Out Hold Time Data Out to Low Impedance Time Data Out to High Impedance Time DQM Data Out Disable Latency 3 0 3 2 - - 7.5 - 3 0 3 2 - - 7.5 - 3 0 3 2 - - 8 - ns ns ns CLK 10 4 Write Cycle 23 24 25 tDPL tDAL tDQW Data input to Precharge (write recovery) Data In to Active/refresh DQM Write Mask Latency 1 5 0 - - - 1 5 0 - - - 1 5 0 - - - CLK CLK CLK 11 V436632Y24V Rev. 1.2 March 2002 8 V436632Y24V CILETIV LESO M Notes: 1. The specified values are valid when addresses are changed no more than once during tCK(min.) and when No Operation commands are registered on every rising clock edge during tRC(min). Values are shown per module bank. 2. The specified values are valid when data inputs (DQ's) are stable during tRC(min.). 3. All AC characteristics are shown for device level. An initial pause of 100 s is required after power-up, then a Precharge All Banks command must be given followed by 8 Auto Refresh (CBR) cycles before the Mode Register Set Operation can begin. 4. AC timing tests have VIL = 0.4V and V IH = 2.4V with the timing referenced to the 1.4V crossover point. The transition time is measured between VIH and VIL. All AC measurements assume tT = 1 ns with the AC output load circuit shown. Specific tac and toh parameters are measured with a 50 pF only, without any resistive termination and with a input signal of 1V / ns edge rate between 0.8V and 2.0V. tCH 2.4V CLOCK 0.4V + 1.4 V 50 Ohm Z=50 Ohm I/O 50 pF tCL tSETUP tHOLD tT INPUT 1.4V tAC tLZ tOH tAC I/O 50 pF 1.4V OUTPUT Measurement conditions for tac and toh tHZ 5. If clock rising time is longer than 1 ns, a time (tT/2 -0.5) ns has to be added to this parameter. 6. Rated at 1.5V 7. If tT is longer than 1 ns, a time (tT -1) ns has to be added to this parameter. 8. Any time that the refresh Period has been exceeded, a minimum of two Auto (CBR) Refresh commands must be given to "wake-up" the device. 9. Self Refresh Exit is a synchronous operation and begins on the 2nd positive clock edge after CKE returns high. Self Refresh Exit is not complete until a time period equal to tRC is satisfied once the Self Refresh Exit command is registered. 10. 11. Referenced to the time which the output achieves the open circuit condition, not to output voltage levels. tDAL is equivalent to tDPL + tRP. V436632Y24V Rev. 1.2 March 2002 9 V436632Y24V CILETIV LESO M Package Diagram 144 Pin SODIMM 144 Pin SODIMM TSOP component package 0.039 1.25 0.787 1 59 61 143 Pin 2 on Backside 3.3V 2.661 Pin 144 on Backside 0.140 0.143 NOTE: 1. All dimensions in inches. Tolerances 0.005 unless otherwise specified. V436632Y24V Rev. 1.2 March 2002 10 V436632Y24V CILETIV LESO M Module Label Information Label Information Module Density MOSEL VITELIC Part Number Criteria of PC100 or PC133 (refer to MVI datasheet) DIMM manufacture date code V436664S24VATG-10PC V436632Y24VXTG-XX 128MB CLX 256MB CLX V436616R24XXX-XX 512MB CLX PC133U-XXX-542-A 0130-M 682165 0130-K682165 Assembly in Taiwan CAS Latency 2 = CL2 3 = CL3 PC133 U - XXX - 54 2 - A UNBUFFERED DIMM CL = 3 or 2 (CLK) tRCD = 3 or 2 (CLK) tRP = 3 or 2 (CLK) 16 8 Based Gerber file Intel(R) PC100 x 16 Based JEDEC SPD Revision 2 tAC = 5.4 ns V436632Y24V Rev. 1.2 March 2002 11 V436632Y24V WORLDWIDE OFFICES U.S.A. 3910 NORTH FIRST STREET SAN JOSE, CA 95134 PHONE: 408-433-6000 FAX: 408-433-0952 WEST 3910 NORTH FIRST STREET SAN JOSE, CA 95134 PHONE: 408-433-6000 FAX: 408-433-0952 The information in this document is subject to change without notice. MOSEL VITELIC makes no commitment to update or keep current the information contained in this document. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of MOSEL-VITELIC. CILETIV LESO M TAIWAN 7F, NO. 102 MIN-CHUAN E. ROAD, SEC. 3 TAIPEI PHONE: 886-2-2545-1213 FAX: 886-2-2545-1209 NO 19 LI HSIN ROAD SCIENCE BASED IND. PARK HSIN CHU, TAIWAN, R.O.C. PHONE: 886-3-579-5888 FAX: 886-3-566-5888 SINGAPORE 10 ANSON ROAD #23-13 INTERNATIONAL PLAZA SINGAPORE 079903 PHONE: 65-3231801 FAX: 65-3237013 UK & IRELAND SUITE 50, GROVEWOOD BUSINESS CENTRE STRATHCLYDE BUSINESS PARK BELLSHILL, LANARKSHIRE, SCOTLAND, ML4 3NQ PHONE: 44-1698-748515 FAX: 44-1698-748516 JAPAN ONZE 1852 BUILDING 6F 2-14-6 SHINTOMI, CHUO-KU TOKYO 104-0041 PHONE: 03-3537-1400 FAX: 03-3537-1402 GERMANY (CONTINENTAL EUROPE & ISRAEL) BENZSTRASSE 32 71083 HERRENBERG GERMANY PHONE: +49 7032 2796-0 FAX: +49 7032 2796 22 U.S. SALES OFFICES CENTRAL / EAST 604 FIELDWOOD CIRCLE RICHARDSON, TX 75081 PHONE: 214-352-3775 FAX: 214-904-9029 (c) Copyright , MOSEL VITELIC Corp. Printed in U.S.A. MOSEL VITELIC subjects its products to normal quality control sampling techniques which are intended to provide an assurance of high quality products suitable for usual commercial applications. MOSEL VITELIC does not do testing appropriate to provide 100% product quality assurance and does not assume any liability for consequential or incidental arising from any use of its products. If such products are to be used in applications in which personal injury might occur from failure, purchaser must do its own quality assurance testing appropriate to such applications. V436632Y24V Rev. 1.2 March 2002 12 |
Price & Availability of V436632Y24VXTG-10PC |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |